Por favor, use este identificador para citar o enlazar este Item:http://hdl.handle.net/20.500.12105/7152
Título
Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Autor(es)
Fecha de publicación
2018-05
Cita
J Vis Exp. 2018 May 2;(135)
Idioma
Inglés
Tipo de documento
research article
Resumen
A well-defined experimental procedure is put forward to evaluate maximum exposure conditions in a worst-case scenario whilst avoiding the uncertainties caused by the use of personal exposimeters (PEMs) as measuring devices: the body shadow effect (BSE), the limited sensitivity range, and the non-identification of the radiation source. An upper bound for exposure levels to EMF in several indoor enclosures has been measured and simulated. The frequency used for the study is 2.4 GHz, as it is the most commonly used band in indoor communications. Although recorded values are well below the International Commission for Non-Ionizing Radiation Protection (ICNIRP) reference levels, there is a particular need to provide reliable exposure levels within particularly sensitive environments. In terms of electromagnetic field (EMF) exposure, limits established in national and international standards for health protection have been set for unperturbed exposure conditions; that is, for real and objective exposure data that have not been altered in any way.
Palabras clave
Engineering | Issue 135 | Wireless Local Area Network (WLAN) | Numeric Dosimetry | PEM Uncertainties | Body Shadow Effect (BSE) | Radiofrequency (RF) Field Exposure | Ray Tracing
MESH
Versión en línea
DOI
Aparece en las colecciones