Mostrar el registro sencillo del ítem

dc.contributor.authorDvorakova, Darina
dc.contributor.authorPulkrabova, Jana
dc.contributor.authorGramblicka, Tomas
dc.contributor.authorPolachova, Andrea
dc.contributor.authorBuresova, Martina
dc.contributor.authorEsteban-Lopez, Marta 
dc.contributor.authorCastaño, Argelia 
dc.contributor.authorNübler, Stefanie
dc.contributor.authorHaji-Abbas-Zarrabi, Karin
dc.contributor.authorKlausner, Nadine
dc.contributor.authorGöen, Thomas
dc.contributor.authorMol, Hans
dc.contributor.authorKoch, Holger M
dc.contributor.authorVaccher, Vincent
dc.contributor.authorAntignac, Jean-Philippe
dc.contributor.authorHaug, Line Småstuen
dc.contributor.authorVorkamp, Katrin
dc.contributor.authorHajslova, Jana
dc.date.accessioned2022-05-06T07:33:37Z
dc.date.available2022-05-06T07:33:37Z
dc.date.issued2021-07-20
dc.identifier.citationEnviron Res. 2021 Jul 20;202:111705.es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/14288
dc.description.abstractThe European Human Biomonitoring Initiative (HBM4EU) is coordinating and advancing human biomonitoring (HBM). For this purpose, a network of laboratories delivering reliable analytical data on human exposure is fundamental. The analytical comparability and accuracy of laboratories analysing flame retardants (FRs) in serum and urine were investigated by a quality assurance/quality control (QA/QC) scheme comprising interlaboratory comparison investigations (ICIs) and external quality assurance schemes (EQUASs). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds performed from 2018 to 2020 for the determination of ten halogenated flame retardants (HFRs) represented by three congeners of polybrominated diphenyl ethers (BDE-47, BDE-153 and BDE-209), two isomers of hexabromocyclododecane (α-HBCD and γ-HBCD), two dechloranes (anti-DP and syn-DP), tetrabromobisphenol A (TBBPA), decabromodiphenylethane (DBDPE), and 2,4,6-tribromophenol (2,4,6-TBP) in serum, and four metabolites of organophosphorus flame retardants (OPFRs) in urine, at two concentration levels. The number of satisfactory results reported by laboratories increased during the four rounds. In the case of HFRs, the scope of the participating laboratories varied substantially (from two to ten) and in most cases did not cover the entire target spectrum of chemicals. The highest participation rate was reached for BDE-47 and BDE-153. The majority of participants achieved more than 70% satisfactory results for these two compounds over all rounds. For other HFRs, the percentage of successful laboratories varied from 44 to 100%. The evaluation of TBBPA, DBDPE, and 2,4,6-TBP was not possible because the number of participating laboratories was too small. Only seven laboratories participated in the ICI/EQUAS scheme for OPFR metabolites and five of them were successful for at least two biomarkers. Nevertheless, the evaluation of laboratory performance using Z-scores in the first three rounds required an alternative approach compared to HFRs because of the small number of participants and the high variability of experts' results. The obtained results within the ICI/EQUAS programme showed a significant core network of comparable European laboratories for HBM of BDE-47, BDE-153, BDE-209, α-HBCD, γ-HBCD, anti-DP, and syn-DP. On the other hand, the data revealed a critically low analytical capacity in Europe for HBM of TBBPA, DBDPE, and 2,4,6-TBP as well as for the OPFR biomarkers.es_ES
dc.description.sponsorshipWe gratefully acknowledge funding by the European Union's Horizon 2020 research and innovation programme under the grant agreement No. 733032.es_ES
dc.language.isoenges_ES
dc.publisherElsevier es_ES
dc.type.hasVersionVoRes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectExternal quality assurance scheme (EQUAS)es_ES
dc.subjectHBM4EUes_ES
dc.subjectHalogenated flame retardants (HFRs)es_ES
dc.subjectHuman biomonitoring (HBM)es_ES
dc.subjectInterlaboratory comparison investigation (ICI)es_ES
dc.subjectOrganophosphorus flame retardants (OPFRs)es_ES
dc.titleInterlaboratory comparison investigations (ICIs) and external quality assurance schemes (EQUASs) for flame retardant analysis in biological matrices: Results from the HBM4EU projectes_ES
dc.typejournal articlees_ES
dc.rights.licenseAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.identifier.pubmedID34297934es_ES
dc.format.volume202es_ES
dc.format.page111705es_ES
dc.identifier.doi10.1016/j.envres.2021.111705es_ES
dc.contributor.funderUnión Europea. Comisión Europea. H2020 es_ES
dc.description.peerreviewedes_ES
dc.identifier.e-issn1096-0953es_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.envres.2021.111705es_ES
dc.identifier.journalEnvironmental Researches_ES
dc.repisalud.centroISCIII::Centro Nacional de Sanidad Ambientales_ES
dc.repisalud.institucionISCIIIes_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/733032/EUes_ES
dc.rights.accessRightsopen accesses_ES


Ficheros en el ítem

Acceso Abierto
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Este Item está sujeto a una licencia Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 Internacional