Publication: Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T.
| dc.contributor.author | Ferreira da Silva, Tiago | |
| dc.contributor.author | Galan-Arriola, Carlos | |
| dc.contributor.author | Montesinos, Paula | |
| dc.contributor.author | Lopez-Martin, Gonzalo J. | |
| dc.contributor.author | Desco, Manuel | |
| dc.contributor.author | Fuster, Valentin | |
| dc.contributor.author | Ibáñez, Borja | |
| dc.contributor.author | Sanchez-Gonzalez, Javier | |
| dc.contributor.funder | Unión Europea. Comisión Europea. H2020 | |
| dc.contributor.funder | Instituto de Salud Carlos III | |
| dc.contributor.funder | Comunidad de Madrid (España) | |
| dc.contributor.funder | Ministerio de Ciencia, Innovación y Universidades (España) | |
| dc.contributor.funder | Fundación ProCNIC | |
| dc.date.accessioned | 2021-07-19T11:27:15Z | |
| dc.date.available | 2021-07-19T11:27:15Z | |
| dc.date.issued | 2020-12 | |
| dc.description.abstract | To propose and validate a novel imaging sequence that uses a single breath-hold whole-heart 3D T1 saturation recovery compressed SENSE rapid acquisition (SACORA) at 3T. The proposed sequence combines flexible saturation time sampling, compressed SENSE, and sharing of saturation pulses between two readouts acquired at different RR intervals. The sequence was compared with a 3D saturation recovery single-shot acquisition (SASHA) implementation with phantom and in vivo experiments (pre and post contrast; 7 pigs) and was validated against the reference inversion recovery spin echo (IR-SE) sequence in phantom experiments. Phantom experiments showed that the T1 maps acquired by 3D SACORA and 3D SASHA agree well with IR-SE. In vivo experiments showed that the pre-contrast and post-contrast T1 maps acquired by 3D SACORA are comparable to the corresponding 3D SASHA maps, despite the shorter acquisition time (15s vs. 188s, for a heart rate of 60 bpm). Mean septal pre-contrast T1 was 1453 ± 44 ms with 3D SACORA and 1460 ± 60 ms with 3D SASHA. Mean septal post-contrast T1 was 824 ± 66 ms and 824 ± 60 ms. 3D SACORA acquires 3D T1 maps in 15 heart beats (heart rate, 60 bpm) at 3T. In addition to its short acquisition time, the sequence achieves good T1 estimation precision and accuracy. | es_ES |
| dc.description.peerreviewed | Sí | es_ES |
| dc.description.sponsorship | TFdS has received funding from the European Union Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement N722427. CGA is a P-FIS fellow (Instituto deSalud Carlos III). This study was partially supported by the Comunidad de Madrid (S2017/BMD-3867 RENIM-CM) and cofunded with European structural and investment funds. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia, Innovación y Universidades (MCNU) and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505). | es_ES |
| dc.format.number | 6 | es_ES |
| dc.format.page | 865-876 | es_ES |
| dc.format.volume | 33 | es_ES |
| dc.identifier.citation | MAGMA. 2020; 33(6):865-876 | es_ES |
| dc.identifier.doi | 10.1007/s10334-020-00848-2 | es_ES |
| dc.identifier.issn | 0968-5243 | es_ES |
| dc.identifier.journal | Magma (New York, N.Y.) | es_ES |
| dc.identifier.pubmedID | 32410103 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/20.500.12105/13247 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Springer | es_ES |
| dc.relation.projectFECYT | info:eu-repo/grantAgreement/ES/S2017/BMD-3867-RENIM-CM | es_ES |
| dc.relation.projectFECYT | info:eu-repo/grantAgreement/ES/SEV-2015-0505 | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/EC/H2020/N722427 | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1007/s10334-020-00848-2 | es_ES |
| dc.repisalud.institucion | CNIC | es_ES |
| dc.repisalud.orgCNIC | CNIC::Grupos de investigación::Laboratorio Traslacional para la Imagen y Terapia Cardiovascular | es_ES |
| dc.repisalud.orgCNIC | CNIC::Grupos de investigación::Imagen Cardiovascular y Estudios Poblacionales | es_ES |
| dc.repisalud.orgCNIC | CNIC::Unidades técnicas::Imagen Avanzada | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.license | Atribución 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
| dc.title | Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T. | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | VoR | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 7a3eb52c-08fc-474a-8bca-e069339a4bc6 | |
| relation.isAuthorOfPublication | 626bd700-c4dc-44c4-8849-c1ac5ffbc7a3 | |
| relation.isAuthorOfPublication | 3d8c68c5-1cf7-41e7-bc20-a44a703ae994 | |
| relation.isAuthorOfPublication | 558474d4-85be-4127-bda8-59128f707249 | |
| relation.isAuthorOfPublication | 2cac8bb6-2bff-4bf6-8209-bdbd21781786 | |
| relation.isAuthorOfPublication | b6428aa3-d242-4efb-a7a2-b977c3aeadd8 | |
| relation.isAuthorOfPublication.latestForDiscovery | 7a3eb52c-08fc-474a-8bca-e069339a4bc6 |


