Publication:
Explicit measurement of multi-tracer arterial input function for PET imaging using blood sampling spectroscopy

dc.contributor.authorVelasco, Carlos
dc.contributor.authorMota-Cobian, Adriana
dc.contributor.authorMateo, Jesus
dc.contributor.authorEspana, Samuel
dc.contributor.funderInstituto de Salud Carlos III
dc.contributor.funderUnión Europea. Fondo Europeo de Desarrollo Regional (FEDER/ERDF)
dc.contributor.funderComunidad de Madrid (España)
dc.contributor.funderMinisterio de Educación (España)
dc.contributor.funderMinisterio de Ciencia, Innovación y Universidades (España)
dc.contributor.funderFundación ProCNIC
dc.date.accessioned2020-03-09T12:52:00Z
dc.date.available2020-03-09T12:52:00Z
dc.date.issued2020-02
dc.description.abstractBACKGROUND: Conventional PET imaging has usually been limited to a single tracer per scan. We propose a new technique for multi-tracer PET imaging that uses dynamic imaging and multi-tracer compartment modeling including an explicitly derived arterial input function (AIF) for each tracer using blood sampling spectroscopy. For that purpose, at least one of the co-injected tracers must be based on a non-pure positron emitter. METHODS: The proposed technique was validated in vivo by performing cardiac PET/CT studies on three healthy pigs injected with 18FDG (viability) and 68Ga-DOTA (myocardial blood flow and extracellular volume fraction) during the same acquisition. Blood samples were collected during the PET scan, and separated AIF for each tracer was obtained by spectroscopic analysis. A multi-tracer compartment model was applied to the myocardium in order to obtain the distribution of each tracer at the end of the PET scan. Relative activities of both tracers and tracer uptake were obtained and compared with the values obtained by ex vivo analysis of excised myocardial tissue segments. RESULTS: A high correlation was obtained between multi-tracer PET results, and those obtained from ex vivo analysis (18FDG relative activity: r = 0.95, p < 0.0001; SUV: r = 0.98, p < 0.0001). CONCLUSIONS: The proposed technique allows performing PET scans with two tracers during the same acquisition obtaining separate information for each tracer.es_ES
dc.description.peerreviewedes_ES
dc.description.sponsorshipThis work was supported by grants from the Carlos III Institute of Health of Spain and Fondo Europeo de Desarrollo Regional (FEDER, “Una manera de hacer Europa”) (FIS-FEDER PI14-01427) and from the Comunidad de Madrid (2016-T1/TIC-1099). CV holds a fellowship from the Spanish Ministry of Education (FPU014/01794). The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia, Innovación y Universidades (MCNU), and the Pro CNIC Foundation and is a Severo Ochoa Center of Excellence (SEV-2015-0505).es_ES
dc.format.number1es_ES
dc.format.page7es_ES
dc.format.volume7es_ES
dc.identifier.citationEJNMMI Phys. 2020; 7(1):7es_ES
dc.identifier.doi10.1186/s40658-020-0277-4es_ES
dc.identifier.issn2197-7364es_ES
dc.identifier.journalEJNMMI physicses_ES
dc.identifier.pubmedID32030519es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/9241
dc.language.isoenges_ES
dc.publisherSpringeres_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/SEV-2015-0505es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/PI14-01427es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/FPU014/01794es_ES
dc.relation.publisherversionhttps://doi.org/10.1186/s40658-020-0277-4es_ES
dc.repisalud.institucionCNICes_ES
dc.repisalud.orgCNICCNIC::Grupos de investigaciónes_ES
dc.repisalud.orgCNICCNIC::Unidades técnicas::Imagen Avanzadaes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectArterial input functiones_ES
dc.subjectGamma spectroscopyes_ES
dc.subjectMulti-tracer PETes_ES
dc.subjectPositron emission tomographyes_ES
dc.titleExplicit measurement of multi-tracer arterial input function for PET imaging using blood sampling spectroscopyes_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication2354bf11-b233-4470-9d45-24b5f0d5f005
relation.isAuthorOfPublication9adc958d-9ef6-4528-b532-68f7f3ad937c
relation.isAuthorOfPublication87474fa8-0391-4061-976d-4576907ea30d
relation.isAuthorOfPublicationaa5c6326-5e02-4c53-afad-fdf9c0115861
relation.isAuthorOfPublication.latestForDiscovery2354bf11-b233-4470-9d45-24b5f0d5f005

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ExplicitMeasurementMulti-tracer_2020.pdf
Size:
1.73 MB
Format:
Adobe Portable Document Format
Description:
Artículo