Publication: Explicit measurement of multi-tracer arterial input function for PET imaging using blood sampling spectroscopy
| dc.contributor.author | Velasco, Carlos | |
| dc.contributor.author | Mota-Cobian, Adriana | |
| dc.contributor.author | Mateo, Jesus | |
| dc.contributor.author | Espana, Samuel | |
| dc.contributor.funder | Instituto de Salud Carlos III | |
| dc.contributor.funder | Unión Europea. Fondo Europeo de Desarrollo Regional (FEDER/ERDF) | |
| dc.contributor.funder | Comunidad de Madrid (España) | |
| dc.contributor.funder | Ministerio de Educación (España) | |
| dc.contributor.funder | Ministerio de Ciencia, Innovación y Universidades (España) | |
| dc.contributor.funder | Fundación ProCNIC | |
| dc.date.accessioned | 2020-03-09T12:52:00Z | |
| dc.date.available | 2020-03-09T12:52:00Z | |
| dc.date.issued | 2020-02 | |
| dc.description.abstract | BACKGROUND: Conventional PET imaging has usually been limited to a single tracer per scan. We propose a new technique for multi-tracer PET imaging that uses dynamic imaging and multi-tracer compartment modeling including an explicitly derived arterial input function (AIF) for each tracer using blood sampling spectroscopy. For that purpose, at least one of the co-injected tracers must be based on a non-pure positron emitter. METHODS: The proposed technique was validated in vivo by performing cardiac PET/CT studies on three healthy pigs injected with 18FDG (viability) and 68Ga-DOTA (myocardial blood flow and extracellular volume fraction) during the same acquisition. Blood samples were collected during the PET scan, and separated AIF for each tracer was obtained by spectroscopic analysis. A multi-tracer compartment model was applied to the myocardium in order to obtain the distribution of each tracer at the end of the PET scan. Relative activities of both tracers and tracer uptake were obtained and compared with the values obtained by ex vivo analysis of excised myocardial tissue segments. RESULTS: A high correlation was obtained between multi-tracer PET results, and those obtained from ex vivo analysis (18FDG relative activity: r = 0.95, p < 0.0001; SUV: r = 0.98, p < 0.0001). CONCLUSIONS: The proposed technique allows performing PET scans with two tracers during the same acquisition obtaining separate information for each tracer. | es_ES |
| dc.description.peerreviewed | Sí | es_ES |
| dc.description.sponsorship | This work was supported by grants from the Carlos III Institute of Health of Spain and Fondo Europeo de Desarrollo Regional (FEDER, “Una manera de hacer Europa”) (FIS-FEDER PI14-01427) and from the Comunidad de Madrid (2016-T1/TIC-1099). CV holds a fellowship from the Spanish Ministry of Education (FPU014/01794). The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia, Innovación y Universidades (MCNU), and the Pro CNIC Foundation and is a Severo Ochoa Center of Excellence (SEV-2015-0505). | es_ES |
| dc.format.number | 1 | es_ES |
| dc.format.page | 7 | es_ES |
| dc.format.volume | 7 | es_ES |
| dc.identifier.citation | EJNMMI Phys. 2020; 7(1):7 | es_ES |
| dc.identifier.doi | 10.1186/s40658-020-0277-4 | es_ES |
| dc.identifier.issn | 2197-7364 | es_ES |
| dc.identifier.journal | EJNMMI physics | es_ES |
| dc.identifier.pubmedID | 32030519 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/20.500.12105/9241 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Springer | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/ES/SEV-2015-0505 | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/ES/PI14-01427 | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/ES/FPU014/01794 | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1186/s40658-020-0277-4 | es_ES |
| dc.repisalud.institucion | CNIC | es_ES |
| dc.repisalud.orgCNIC | CNIC::Grupos de investigación | es_ES |
| dc.repisalud.orgCNIC | CNIC::Unidades técnicas::Imagen Avanzada | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.license | Atribución 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
| dc.subject | Arterial input function | es_ES |
| dc.subject | Gamma spectroscopy | es_ES |
| dc.subject | Multi-tracer PET | es_ES |
| dc.subject | Positron emission tomography | es_ES |
| dc.title | Explicit measurement of multi-tracer arterial input function for PET imaging using blood sampling spectroscopy | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | VoR | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 2354bf11-b233-4470-9d45-24b5f0d5f005 | |
| relation.isAuthorOfPublication | 9adc958d-9ef6-4528-b532-68f7f3ad937c | |
| relation.isAuthorOfPublication | 87474fa8-0391-4061-976d-4576907ea30d | |
| relation.isAuthorOfPublication | aa5c6326-5e02-4c53-afad-fdf9c0115861 | |
| relation.isAuthorOfPublication.latestForDiscovery | 2354bf11-b233-4470-9d45-24b5f0d5f005 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- ExplicitMeasurementMulti-tracer_2020.pdf
- Size:
- 1.73 MB
- Format:
- Adobe Portable Document Format
- Description:
- Artículo


