dc.description.abstractLow glucose levels during exercise may lead to hypoglycemia, which can have grave consequences in diabetic athletes. Mobile colorimetric wearable biosensors that measure glucose levels in sweat are ideal for self-monitoring as they can utilize the camera in smartphones for signal reading. However, colorimetric biosensors proposed thus far have higher limit of detection (LOD) than electrochemical devices, which makes them unsuitable for detecting hypoglycemia. In this manuscript we describe colorimetric wearable biosensors that detect glucose in sweat with an LOD of 0.01 mM and a dynamic range up to 0.15 mM. The devices are made of filter paper and incorporate a sweat volume sensor and a color chart for signal correction. The biosensors do not suffer from interferences originated by delayed sample readings, or differences in bending angle and sample pH. When applied to volunteers performing an exercise routine, sweat glucose levels corrected with sweat volume measurements correlated well with blood glucose measurements performed with a commercial device. The devices are lightweight and easily disposable. These features, along with the smartphone-based colorimetric readout, makes them promising as over-the-counter tests for measuring glucose levels non-invasively during exercise.en
dc.description.sponsorshipR. R. and E. B. acknowledge funding from IdISBa/Impost turisme sostenible/Agencia d'Estrategia Turistica de les Illes Balears-Govern de les Illes Balears through a Radix and Folium fellow-ships, respectively. E. B. acknowledges funding from the Instituto de Salud Carlos III (Sara Borrell contract). A. V. acknowledges funding from European Social Fund (ESF) through JoTReSdOS program. Open access is granted by funds from the Liberi program (IdISBa).es_ES
dc.format.number10es_ES
dc.format.page3273-3279es_ES
dc.format.volume146es_ES
dc.identifier.citationVaquer A, Baron E, de la Rica R. Detection of low glucose levels in sweat with colorimetric wearable biosensors. Analyst. 2021 May 21;146(10):3273-9.en
dc.identifier.doi10.1039/d1an00283j
dc.identifier.e-issn1364-5528es_ES
dc.identifier.issn0003-2654
dc.identifier.journalAnalystes_ES
dc.identifier.otherhttps://hdl.handle.net/20.500.13003/19531
dc.identifier.pubmedID33999074es_ES
dc.identifier.puiL635103884
dc.identifier.scopus2-s2.0-85106199081
dc.identifier.urihttps://hdl.handle.net/20.500.12105/23339
dc.identifier.wos639421700001
dc.language.isoengen
dc.publisherRoyal Society of Chemistry (RSC)
dc.relation.publisherversionhttps://dx.doi.org/10.1039/d1an00283jen
dc.rights.accessRightsopen accessen
dc.rights.licenseAttribution-NonCommercial 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subject.decsColorimetría*
dc.subject.decsSudor*
dc.subject.decsHumanos*
dc.subject.decsGlucosa*
dc.subject.decsDispositivos Electrónicos Vestibles*
dc.subject.decsTécnicas Biosensibles*
dc.subject.meshGlucose*
dc.subject.meshColorimetry*
dc.subject.meshWearable Electronic Devices*
dc.subject.meshHumans*
dc.subject.meshBiosensing Techniques*
dc.subject.meshSweat*
dc.titleDetection of low glucose levels in sweat with colorimetric wearable biosensorsen
dc.typeresearch articleen
dspace.entity.typePublication
relation.isPublisherOfPublicationf873b730-a584-43b3-9018-d156aa9d413f
relation.isPublisherOfPublication.latestForDiscoveryf873b730-a584-43b3-9018-d156aa9d413f

Files