Publication:
Optimizing the Limit of Detection of Waveguide-Based Interferometric Biosensor Devices

dc.contributor.authorLeuermann, Jonas
dc.contributor.authorFernández-Gavela, Adrián
dc.contributor.authorTorres-Cubillo, Antonia
dc.contributor.authorPostigo, Sergio
dc.contributor.authorSánchez-Postigo, Alejandro
dc.contributor.authorLechuga, Laura M.
dc.contributor.authorHalir, Robert
dc.contributor.authorMolina-Fernández, Íñigo
dc.contributor.authoraffiliation[Leuermann,J; Halir,R; Molina-Fernández,I] Bionand Center for Nanomedicine and Biotechnology, Málaga, Spain. [Leuermann,J; Torres-Cubillo,A; Sánchez-Postigo,A; Halir,R; Molina-Fernández,I] Department de Ingeniería de Comunicaciones, Universidad de Málaga, ETSI Telecomunicación, Málaga, Spain. [Fernández-Gavela,A] Departamento de Física, Universidad de Oviedo, Oviedo, Spain. [Postigo,S] Department de Ingeniería Mecánica, Universidad de Málaga, Térmica y de Fluidos, Escuela de Ingenierías Industriales, Málaga, Spain. [Lechuga,LM] Nanobiosensors and Bioanalytical Applications Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, BIST and CIBER-BBN Campus UAB, Barcelona, Spain.
dc.date.accessioned2024-02-10T20:02:02Z
dc.date.available2024-02-10T20:02:02Z
dc.date.issued2019-08-23
dc.description.abstractWaveguide-based photonic sensors provide a unique combination of high sensitivity, compact size and label-free, multiplexed operation. Interferometric configurations furthermore enable a simple, fixed-wavelength read-out making them particularly suitable for low-cost diagnostic and monitoring devices. Their limit of detection, i.e., the lowest analyte concentration that can be reliably observed, mainly depends on the sensors response to small refractive index changes, and the noise in the read-out system. While enhancements in the sensors response have been extensively studied, noise optimization has received much less attention. Here we show that order-of-magnitude enhancements in the limit of detection can be achieved through systematic noise reduction, and demonstrate a limit of detection of ∼ 10−8RIU with a silicon nitride sensor operating at telecom wavelengths.
dc.description.sponsorshipThis project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 713721. We would like to acknowledge the Ministerio de Economía y Competitividad, Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad (cofinanciado FEDER), Proyecto TEC2016-80718-R, and the Universidad de Málaga. Proyecto I+D+i en el marco del Programa Operativo FEDER Andalucía 2014-2020 (UMA18-FEDERJA-219). ICN2 is supported by the Severo Ochoa program from Spanish MINECO (Grant No. SEV-2017-0706).
dc.identifier.doi10.3390/s19173671
dc.identifier.e-issn1424-8220es_ES
dc.identifier.journalSensorses_ES
dc.identifier.otherhttp://hdl.handle.net/10668/3341
dc.identifier.pubmedID31450817es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/17902
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/19/17/3671es
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectBiosensors
dc.subjectCoherent detection
dc.subjectInterferometer
dc.subjectLimit of detection
dc.subjectSilicon photonics
dc.subjectTécnicas biosensibles
dc.subjectLímite de detección
dc.subject.meshBiosensing Techniques
dc.subject.meshInterferometry
dc.subject.meshLimit of Detection
dc.titleOptimizing the Limit of Detection of Waveguide-Based Interferometric Biosensor Devices
dc.typeresearch article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isPublisherOfPublication30293a55-0e53-431f-ae8c-14ab01127be9
relation.isPublisherOfPublication.latestForDiscovery30293a55-0e53-431f-ae8c-14ab01127be9

Files