Publication:
Accurate quantification of atherosclerotic plaque volume by 3D vascular ultrasound using the volumetric linear array method.

dc.contributor.authorLopez-Melgar, Beatriz
dc.contributor.authorFernandez-Friera, Leticia
dc.contributor.authorSanchez-Gonzalez, Javier
dc.contributor.authorVilchez, Jean Paul
dc.contributor.authorCecconi, Alberto
dc.contributor.authorMateo, Jesus
dc.contributor.authorPeñalvo, Jose L
dc.contributor.authorOliva, Belen
dc.contributor.authorGarcia-Ruiz, Jose M
dc.contributor.authorKauffman, Steve
dc.contributor.authorJimenez-Borreguero, Luis J.
dc.contributor.authorRuiz-Cabello, Jesus
dc.contributor.authorFernandez-Ortiz, Antonio
dc.contributor.authorIbáñez, Borja
dc.contributor.authorFuster, Valentin
dc.contributor.funderSociedad Española de Cardiología
dc.date.accessioned2021-02-12T11:10:43Z
dc.date.available2021-02-12T11:10:43Z
dc.date.issued2016-05
dc.description.abstractDirect quantification of atherosclerotic plaque volume by three-dimensional vascular ultrasound (3DVUS) is more reproducible than 2DUS-based three-dimensional (2D/3D) techniques that generate pseudo-3D volumes from summed 2D plaque areas; however, its accuracy has not been reported. We aimed to determine 3DVUS accuracy for plaque volume measurement with special emphasis on small plaques (a hallmark of early atherosclerosis). The in vitro study consisted of nine phantoms of different volumes (small and medium-large) embedded at variable distances from the surface (superficial vs. >5 cm-depth) and comparison of 3DVUS data generated using a novel volumetric-linear array method with the real phantom volumes. The in vivo study was undertaken in a rabbit model of atherosclerosis in which 3DVUS and 2D/3D volume measurements were correlated against gold-standard histological measurements. In the in vitro setting, there was a strong correlation between 3DVUS measures and real phantom volume both for small (3.0-64.5 mm(3) size) and medium-large (91.1-965.5 mm(3) size) phantoms embedded superficially, with intraclass correlation coefficients (ICC) of 0.99 and 0.98, respectively; conversely, when phantoms were placed at >5 cm, the correlation was only moderate (ICC = 0.67). In the in vivo setting there was strong correlation between 3DVUS-measured plaque volumes and the histological gold-standard (ICC = 0.99 [4.02-92.5 mm(3) size]). Conversely, the correlation between 2D/3D values and the histological gold standard (sum of plaque areas) was weaker (ICC = 0.87 [49-520 mm(2) size]), with large dispersion of the differences between measurements in Bland-Altman plots (mean error, 79.2 mm(2)). 3DVUS using the volumetric-linear array method accurately measures plaque volumes, including those of small plaques. Measurements are more accurate for superficial arterial territories than for deep territories.es_ES
dc.description.peerreviewedes_ES
dc.format.page230-7es_ES
dc.format.volume248es_ES
dc.identifier.citationAtherosclerosis. 2016; 248:230-237es_ES
dc.identifier.doi10.1016/j.atherosclerosis.2016.03.002es_ES
dc.identifier.issn0021-9150
dc.identifier.journalAtherosclerosises_ES
dc.identifier.pubmedID27038420es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/11871
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.atherosclerosis.2016.03.002es_ES
dc.repisalud.institucionCNICes_ES
dc.repisalud.orgCNICCNIC::Unidades técnicas::Imagen Avanzadaes_ES
dc.repisalud.orgCNICCNIC::Grupos de investigación::Imagen Cardiovascular y Estudios Poblacionaleses_ES
dc.repisalud.orgCNICCNIC::Grupos de investigación::Laboratorio Traslacional para la Imagen y Terapia Cardiovasculares_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.meshUltrasonographyes_ES
dc.subject.meshAnimalses_ES
dc.subject.meshCohort Studieses_ES
dc.subject.meshHumanses_ES
dc.subject.meshImage Processing, Computer-Assistedes_ES
dc.subject.meshImaging, Three-Dimensionales_ES
dc.subject.meshLinear Modelses_ES
dc.subject.meshPhantoms, Imaginges_ES
dc.subject.meshPlaque, Atherosclerotices_ES
dc.subject.meshRabbitses_ES
dc.subject.meshReproducibility of Resultses_ES
dc.subject.meshSoftwarees_ES
dc.titleAccurate quantification of atherosclerotic plaque volume by 3D vascular ultrasound using the volumetric linear array method.es_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicatione0026bba-db67-4a42-8fa8-79005fe4857e
relation.isAuthorOfPublication4b2a0672-e9a0-4788-b256-d3170c84aab2
relation.isAuthorOfPublicationb6428aa3-d242-4efb-a7a2-b977c3aeadd8
relation.isAuthorOfPublication0f4bce38-7cd9-4ea3-b824-809883c1ef42
relation.isAuthorOfPublication87474fa8-0391-4061-976d-4576907ea30d
relation.isAuthorOfPublication069f0592-c0c0-465f-bae7-3dcdaa48f796
relation.isAuthorOfPublication2cac2b58-fa25-494c-92c5-5ac91f3d2036
relation.isAuthorOfPublicationf8bdc86d-5800-41d9-865a-bf567a8acf9f
relation.isAuthorOfPublication845644de-01dd-4517-ab89-a07183d31248
relation.isAuthorOfPublicationc247543c-ab71-441c-8eec-b54f56c6a1ff
relation.isAuthorOfPublication2cac8bb6-2bff-4bf6-8209-bdbd21781786
relation.isAuthorOfPublication558474d4-85be-4127-bda8-59128f707249
relation.isAuthorOfPublication.latestForDiscoverye0026bba-db67-4a42-8fa8-79005fe4857e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AccurateQuantificationOfAtherosclerotic_2016.pdf
Size:
966.04 KB
Format:
Adobe Portable Document Format
Description:
Versión Postprint Revisada