Publication:
Reproducibility of Three-Dimensional Vascular Ultrasound for the Detection and Quantification of Early Atherosclerosis: A FAMILIA Substudy

dc.contributor.authorFernandez-Jimenez, Rodrigo
dc.contributor.authorGraziano-Zill, Christine
dc.contributor.authorBenkader, Latifa
dc.contributor.authorDiaz-Munoz, Raquel
dc.contributor.authorJaslow, Risa
dc.contributor.authorKasarskis, Andrew
dc.contributor.authorHajjar, Roger J
dc.contributor.authorKadian-Dodov, Daniella
dc.contributor.authorFayad, Zahi A
dc.contributor.authorFuster, Valentin
dc.contributor.funderAmerican Heart Association
dc.contributor.funderUnión Europea. Comisión Europea
dc.contributor.funderMinisterio de Ciencia, Innovación y Universidades (España)
dc.date.accessioned2019-02-05T14:27:05Z
dc.date.available2019-02-05T14:27:05Z
dc.date.issued2018-11-10
dc.descriptionAmerican Heart Association Scientific Sessions 2018. Chicago, USA. November 10-12, 2018.es_ES
dc.description.abstractIntroduction: Three-dimensional vascular ultrasound (3DVUS) offers promise for cardiovascular risk stratification in the general population. However, 3DVUS reproducibility in early stages of atherosclerosis disease has not been well stablished. Objective: To determine 3DVUS agreement and reproducibility for plaque detection and focal atherosclerosis disease burden quantification in bilateral carotid and ileofemoral territories in adults enrolled in the “Family-Based Approach in a Minority Community Integrating Systems-Biology for Promotion of Health” (FAMILIA) study. Methods: A total of 772 vascular territories were studied by 3DVUS at baseline in a random sample of 193 adults, including parents/caregivers and staff, recruited in the FAMILIA study from 15 Head Start preschools in Harlem (New York). The acquired images were analyzed off-line using the Vascular Plaque Quantification tool in QLAB, by two independent experienced technicians. Prevalence-adjusted and bias-adjusted kappa (PABAK) coefficients were calculated to assess the intraobserver and interobserver agreement for plaque detection. For intraobserver and interobserver reproducibility analyses of focal atherosclerosis disease burden (plaque volume quantification), the intraclass correlation coefficient (ICC) and Bland-Altman plots were employed in all plaque-positive participants recruited in the FAMILIA trial (n = 46 adult participants). Results: Mean age of studied FAMILIA adult participants was 37.8±11.4 years, 85% female, 64% Hispanic/Latino, 26% Non-Hispanic Black. The overall prevalence of atherosclerosis was 8.3 %. Intraobserver and interobserver agreement was excellent for the detection of plaque (PABAK ranging from 0.97 to 1) and good for focal disease burden quantification (average ICC >0.85 in all cases). No significant intraobserver or interobserver bias was detected in Bland-Altman plots. Conclusion: 3DVUS shows excellent intraobserver and interobserver agreement and good reproducibility for the detection and quantification of focal disease in early stages of atherosclerosis. Thus, 3DVUS could be used as a tool for subclinical atherosclerosis screening and for promoting healthy habits in the general population.es_ES
dc.identifier.citationCirculation. 2018; 138 (Suppl_1): A16376es_ES
dc.identifier.doi10.1161/circ.138.suppl_1.16376es_ES
dc.identifier.issn0009-7322es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/7119
dc.language.isoenges_ES
dc.relation.publisherversionhttps://www.ahajournals.org/doi/10.1161/circ.138.suppl_1.16376es_ES
dc.repisalud.institucionCNICes_ES
dc.repisalud.orgCNICCNIC::Grupos de investigación::Laboratorio Traslacional para la Imagen y Terapia Cardiovasculares_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.titleReproducibility of Three-Dimensional Vascular Ultrasound for the Detection and Quantification of Early Atherosclerosis: A FAMILIA Substudyes_ES
dc.typeconference posteres_ES
dc.type.hasVersionSMURes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationa6bead57-638c-4bc1-96de-94d972aa3e2c
relation.isAuthorOfPublication558474d4-85be-4127-bda8-59128f707249
relation.isAuthorOfPublication.latestForDiscoverya6bead57-638c-4bc1-96de-94d972aa3e2c

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Reproducibility 3DUS FAMILIA_AHA 2018.pdf
Size:
684.23 KB
Format:
Adobe Portable Document Format
Description:
Poster