Publication: Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting
Loading...
Identifiers
ISSN: 0277-0903
Full text access: http://hdl.handle.net/20.500.13003/11328
SCOPUS: 2-s2.0-84958038358
WOS: 373515900013
Publication date
Advisors
Journal Title
Journal ISSN
Volume Title
Publishers
Abstract
Objective: Correct inhaler technique is central to effective delivery of asthma therapy. The study aim was to identify factors associated with serious inhaler technique errors and their prevalence among primary care patients with asthma using the Diskus dry powder inhaler (DPI). Methods: This was a historical, multinational, cross-sectional study (2011-2013) using the iHARP database, an international initiative that includes patient- and healthcare provider-reported questionnaires from eight countries. Patients with asthma were observed for serious inhaler errors by trained healthcare providers as predefined by the iHARP steering committee. Multivariable logistic regression, stepwise reduced, was used to identify clinical characteristics and asthma-related outcomes associated with 1 serious errors. Results: Of 3681 patients with asthma, 623 (17%) were using a Diskus (mean [SD] age, 51 [14]; 61% women). A total of 341 (55%) patients made 1 serious errors. The most common errors were the failure to exhale before inhalation, insufficient breath-hold at the end of inhalation, and inhalation that was not forceful from the start. Factors significantly associated with 1 serious errors included asthma-related hospitalization the previous year (odds ratio [OR] 2.07; 95% confidence interval [CI], 1.26-3.40); obesity (OR 1.75; 1.17-2.63); poor asthma control the previous 4 weeks (OR 1.57; 1.04-2.36); female sex (OR 1.51; 1.08-2.10); and no inhaler technique review during the previous year (OR 1.45; 1.04-2.02). Conclusions: Patients with evidence of poor asthma control should be targeted for a review of their inhaler technique even when using a device thought to have a low error rate.
Description
DeCS Terms
Índice de Masa Corporal Modelos Logísticos Oportunidad Relativa Prevalencia Femenino Administración por Inhalación Masculino Factores Sexuales Estudios Transversales Factores de Riesgo Humanos Persona de Mediana Edad Escolaridad Factores de Edad Anciano Asma Diseño de Equipo Atención Primaria de Salud Adulto Inhaladores de Polvo Seco
Bibliographic citation
Westerik Janine AM, Carter V, Chrystyn H, Burden A, Thompson SL, Ryan D, et al. Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting. J Asthma. 2016 Mar 15;53(3):321-9. Epub 2016 Jan 26.





