Publication:
Evaluation of the recombinant antigens B2t and 2B2t, compared with hydatid fluid, in IgG-ELISA and immunostrips for the diagnosis and follow up of CE patients

dc.contributor.authorHernandez-Gonzalez, Ana
dc.contributor.authorSánchez-Ovejero, Carlos
dc.contributor.authorManzano-Román, Raúl
dc.contributor.authorGonzález Sánchez, María
dc.contributor.authorDelgado, José Manuel
dc.contributor.authorPardo-García, Teresa
dc.contributor.authorSoriano-Gálvez, Francisco
dc.contributor.authorAkhan, Okan
dc.contributor.authorCretu, Carmen M
dc.contributor.authorVutova, Kamenna
dc.contributor.authorTamarozzi, Francesca
dc.contributor.authorMariconti, Mara
dc.contributor.authorBrunetti, Enrico
dc.contributor.authorVola, Ambra
dc.contributor.authorFabiani, Massimo
dc.contributor.authorCasulli, Adriano
dc.contributor.authorSiles-Lucas, Mar
dc.contributor.funderUnión Europea
dc.date.accessioned2019-11-26T08:24:34Z
dc.date.available2019-11-26T08:24:34Z
dc.date.issued2018
dc.description.abstractCystic echinococcosis (CE) is one of the most widespread helminthic zoonoses and is caused by the tapeworm Echinococcus granulosus complex. CE diagnosis and monitoring primarily rely on imaging techniques, complemented by serology. This is usually approached by the detection of IgG antibodies against hydatid fluid (HF), but the use of this heterogeneous antigenic mixture results in a variable percentage of false positive and negative results, and has shown to be useless for follow-up due to the long persistence of anti-HF antibodies in cured patients. To improve test performances and standardization, a number of recombinant antigens mainly derived from HF have been described, among them the B2t and 2B2t antigens. The performance of these antigens in the diagnosis and follow up of patients with CE has been so far evaluated on a limited number of samples. Here, we evaluated the performances of tests based on B2t and 2B2t recombinant antigens compared to HF in IgG-ELISA and immunochromatography (IC) for the diagnosis and follow-up of patients with CE in a retrospective cohort study. A total of 721 serum samples were collected: 587 from 253 patients with CE diagnosed by ultrasonography (US), 42 from patients with alveolar echinococcosis and 92 from healthy donors from Salamanca (Spain). The highest overall sensitivity was obtained with HF in ELISA (85.5%), followed by IC containing HF and 2B2t-HF (83.0% and 78.2%, respectively). The lowest sensitivity was obtained with B2t and 2B2t in ELISA (51.8%). The highest specificity was obtained with IC containing 2B2t-HF (100%), and the lowest with HF-ELISA (78.0%). The lowest cross-reactivity with sera from patients with alveolar echinococcosis was detected with the recombinant antigens in ELISA (9.5% - 16.7%) and the highest with the HF-IC (64.3%). The results of B2t and 2B2t-ELISA were influenced by cyst stage, as classified by US according to the WHO-Informal Working Group on Echinococcosis (WHO-IWGE), with low sensitivity for inactive (CE4 and CE5) cysts, and by the drug treatment, with higher sensitivity in patients after drug treatment compared with patients not subjected to drug treatment. The two recombinant antigens in ELISA provided promising results for monitoring patients in follow-up, although their use is limited to patients with positive serology against them at the beginning of the follow-up. Potential biological reasons behind the low sensitivity of the recombinant antigens and possible strategies to enhance the performance of CE serology are discussed.es_ES
dc.description.peerreviewedes_ES
dc.description.sponsorshipThis research received funding from the European Community’s Seventh Framework Programme under the grant agreement 602051 (Project HERACLES: Human cystic Echinococcosis ReseArch in CentraL and Eastern Societies; http://www.heracles-fp7.eu/). The funding body had no involvement in the conception, preparation and writing of the manuscript, in the viewpoints expressed, nor in the decision to submit this article.es_ES
dc.format.number9es_ES
dc.format.pagee0006741es_ES
dc.format.volume12es_ES
dc.identifier.citationPLoS Negl Trop Dis. 2018 Sep 6;12(9):e0006741.es_ES
dc.identifier.doi10.1371/journal.pntd.0006741es_ES
dc.identifier.e-issn1935-2735es_ES
dc.identifier.issn1935-2735es_ES
dc.identifier.journalPLoS neglected tropical diseaseses_ES
dc.identifier.pubmedID30188936es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/8712
dc.language.isoenges_ES
dc.publisherPublic Library of Science (PLOS)es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/602051/EUes_ES
dc.relation.publisherversionhttps://doi.org/10.1371/journal.pntd.0006741es_ES
dc.repisalud.centroISCIII::Centro Nacional de Microbiologíaes_ES
dc.repisalud.institucionISCIIIes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.meshAdultes_ES
dc.subject.meshAgedes_ES
dc.titleEvaluation of the recombinant antigens B2t and 2B2t, compared with hydatid fluid, in IgG-ELISA and immunostrips for the diagnosis and follow up of CE patientses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication6cba8d59-ce7c-40ed-bec9-a32fcfb9bff8
relation.isAuthorOfPublication.latestForDiscovery6cba8d59-ce7c-40ed-bec9-a32fcfb9bff8

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
EvaluationOfTheRecombinant_2018.pdf
Size:
1.7 MB
Format:
Adobe Portable Document Format
Description: