Publication:
Two Sporadic Cases of Legionellosis Associated with the Use of Domestic Ultrasonic Humidifiers

dc.contributor.authorReinares Ortiz, Javier
dc.contributor.authorPérez-Serrano, Jorge
dc.contributor.authorGonzález-Rubio, Juana María
dc.contributor.authorGonzalez-Camacho, Fernando
dc.contributor.funderInstituto de Salud Carlos III
dc.date.accessioned2025-01-10T15:54:51Z
dc.date.available2025-01-10T15:54:51Z
dc.date.issued2024-10-25
dc.description.abstractTwo sporadic cases of legionellosis occurring in consecutive years were confirmed by positive antigenuria to serogroup 1 in individuals with limited mobility who were confined to their homes. Both cases had a history of using ultrasonic humidifiers and of low exposure to other possible sources of infection. This study was conducted through an expanded epidemiological survey and home inspection. Samples were collected from domestic hot water and humidifiers. Environmental isolates were characterised by immunoagglutination and immunofluorescence. The Dresden panel is employed for the determination of groups and subgroups of serogroup 1. The amoebae were isolated by water filtration and subsequent cultivation of the filters. Identification of the isolates was conducted through the sequencing of PCR products. In both cases, epidemiological studies identified the ultrasonic humidifiers as the probable source of infection. The presence of was confirmed in the sanitary water installation and in the humidifiers, where high values of serogroup 1 counts were also obtained. The isolates were characterised as Olda Oxford and Olda OLDA. Furthermore, in addition to the Legionella isolates, the presence of was also identified in samples obtained from domestic hot water and humidifiers in one of the residential addresses under investigation. It has been demonstrated that humidifiers can act as an amplification mechanism for pathogenic microorganisms when they are not cleaned and maintained correctly. This can pose a health danger, especially to people with previous respiratory pathologies, the immunosuppressed, and the elderly. Therefore, it is of the utmost importance that professionals who recommend the therapeutic use of this equipment should issue warnings regarding the importance of its correct use, cleaning, and disinfection. Finally, humidifiers should be considered in epidemiological surveys and in the study of sporadic cases.
dc.description.peerreviewed
dc.description.sponsorshipThis research was funded by the Instituto de Salud Carlos III [AESI-2022 MPY 341/22 project to F.G-C.].
dc.format.number11
dc.format.page2139
dc.format.volume12
dc.identifier.citationReinares Ortiz J, Pérez-Serrano J, González-Rubio JM, González-Camacho F. Two Sporadic Cases of Legionellosis Associated with the Use of Domestic Ultrasonic Humidifiers. Microorganisms. 2024 Oct 25;12(11):2139.
dc.identifier.doi10.3390/microorganisms12112139
dc.identifier.e-issn2076-2607
dc.identifier.journalMicroorganisms
dc.identifier.pubmedID39597529
dc.identifier.urihttps://hdl.handle.net/20.500.12105/25994
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/MPY341/22
dc.relation.publisherversionhttps://doi.org/10.3390/microorganisms12112139
dc.repisalud.centroISCIII::Centro Nacional de Microbiología (CNM)
dc.repisalud.institucionISCIII
dc.rights.accessRightsopen access
dc.rights.licenseAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectLegionella pneumophila
dc.subjectHumidifier
dc.subjectLegionnaires’ disease
dc.subjectSporadic case
dc.titleTwo Sporadic Cases of Legionellosis Associated with the Use of Domestic Ultrasonic Humidifiers
dc.typeresearch article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication5c3bb6d2-1678-45d5-85fd-b088c1c4ccb9
relation.isAuthorOfPublicationae7e52c4-61ca-4e4e-bd39-6051922e30ef
relation.isAuthorOfPublication.latestForDiscovery5c3bb6d2-1678-45d5-85fd-b088c1c4ccb9
relation.isFunderOfPublication7d739953-4b68-4675-b5bb-387a9ab74b66
relation.isFunderOfPublication.latestForDiscovery7d739953-4b68-4675-b5bb-387a9ab74b66
relation.isPublisherOfPublication30293a55-0e53-431f-ae8c-14ab01127be9
relation.isPublisherOfPublication.latestForDiscovery30293a55-0e53-431f-ae8c-14ab01127be9

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TwoSporadicCasesLegionellosis_2024.pdf
Size:
417.61 KB
Format:
Adobe Portable Document Format