dc.contributor.authoraffiliation[Hidalgo-López,JA; Oballe-Peinado,Ó; Castellanos-Ramos,J; Sánchez-Durán,JA] Departamento de Electrónica, Universidad de Málaga, Andalucía Tech, Málaga, Spain. [Oballe-Peinado,Ó; Castellanos-Ramos,J; Sánchez-Durán,JA] Instituto de Investigación Biomédica de Málaga (IBIMA), Málaga, Spain.
dc.date.accessioned2024-02-19T15:25:13Z
dc.date.available2024-02-19T15:25:13Z
dc.date.issued2021-02-22
dc.description.abstractDirect interface circuits (DICs) avoid the need for signal conditioning circuits and analog-to-digital converters (ADCs) to obtain digital measurements of resistive sensors using only a few passive elements. However, such simple hardware can lead to quantization errors when measuring small resistance values as well as high measurement times and uncertainties for high resistances. Different solutions to some of these problems have been presented in the literature over recent years, although the increased uncertainty in measurements at higher resistance values is a problem that has remained unaddressed. This article presents an economical hardware solution that only requires an extra capacitor to reduce this problem. The circuit is implemented with a field-programmable gate array (FPGA) as a programmable digital device. The new proposal significantly reduces the uncertainty in the time measurements. As a result, the high resistance errors decreased by up to 90%. The circuit requires three capacitor discharge cycles, as is needed in a classic DIC. Therefore, the time to estimate resistance increases slightly, between 2.7% and 4.6%.
dc.description.sponsorshipThis work was funded by the Spanish Government and by the European ERDF program funds under contract TEC2015-67642-R.
dc.identifier.doi10.3390/s21041524
dc.identifier.e-issn1424-8220es_ES
dc.identifier.journalSensorses_ES
dc.identifier.otherhttp://hdl.handle.net/10668/3771
dc.identifier.pubmedID33671720es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/18266
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/21/4/1524/htm#es
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAttribution 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectDirect interface circuits
dc.subjectInterface sensor
dc.subjectResistive sensor
dc.subjectTime-based measurement
dc.subjectCalibration methods
dc.subjectUncertainty
dc.subjectIncertidumbre
dc.subjectRedes neurales de la computación
dc.subjectComputadoras de mano
dc.subject.meshPatient Discharge
dc.subject.meshUncertainty
dc.subject.meshHumans
dc.subject.meshNeural Networks (Computer)
dc.subject.meshAlgorithms
dc.subject.meshComputers, Handheld
dc.subject.meshAnalog-Digital Conversion
dc.subject.meshComputers
dc.subject.meshCalibration
dc.titleTwo-Capacitor Direct Interface Circuit for Resistive Sensor Measurements
dc.typeresearch article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isPublisherOfPublication30293a55-0e53-431f-ae8c-14ab01127be9
relation.isPublisherOfPublication.latestForDiscovery30293a55-0e53-431f-ae8c-14ab01127be9

Files