Publication:
Evaluation of electromagnetic dosimetry of wireless systems in complex indoor scenarios with human body interaction

dc.contributor.authorAguirre, Erik
dc.contributor.authorArpon, Javier
dc.contributor.authorAzpilicueta, Leire
dc.contributor.authorMiguel-Bilbao, Silvia de
dc.contributor.authorRamos-Gonzalez, Maria Victoria
dc.contributor.authorFalcone, Francisco J.
dc.contributor.funderGobierno de Navarra (España)
dc.date.accessioned2018-06-26T15:07:34Z
dc.date.available2018-06-26T15:07:34Z
dc.date.issued2012
dc.description.abstractIn this work, the influence of human body within the estimation of dosimetric values is analyzed. A simplified human body model, including the dispersive nature of material parameters of internal organs, skin, muscle, bones and other elements has been implemented. Such a model has been included within an indoor scenario in which an in-house 3D ray launching code has been applied to estimate received power levels within the complete scenario. The results enhance previous dosimetric estimations, while giving insight on influence of human body model in power level distribution and enabling to analyze the impact in the complete volume of the scenario.es_ES
dc.description.peerreviewedSíes_ES
dc.description.sponsorshipThe authors wish to acknowledge the financial support of project FASTER, funded by the Consejería de Industria, Gobierno de Navarra.es_ES
dc.format.page209es_ES
dc.format.volume43es_ES
dc.identifier.citationProgress In Electromagnetics Research B, 2012;43:189-209es_ES
dc.identifier.doi10.2528/PIERB12070904es_ES
dc.identifier.issn1937-6472es_ES
dc.identifier.journalProgress In Electromagnetics Research Bes_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/6281
dc.language.isoenges_ES
dc.publisherProgress In Electromagnetics Research Bes_ES
dc.relation.publisherversionhttps://dx.doi.org/ 10.2528/PIERB12070904es_ES
dc.repisalud.centroISCIIIes_ES
dc.repisalud.institucionISCIIIes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectHuman body interactiones_ES
dc.subjectIndoor environmentses_ES
dc.subjectDosimetric estimationses_ES
dc.titleEvaluation of electromagnetic dosimetry of wireless systems in complex indoor scenarios with human body interactiones_ES
dc.typeresearch articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication9dc0dff0-892c-4d9e-a8e7-1b7f8f8151f7
relation.isAuthorOfPublicationbfe286e1-284c-45f6-9c5c-a9c22da64eeb
relation.isAuthorOfPublication.latestForDiscovery9dc0dff0-892c-4d9e-a8e7-1b7f8f8151f7
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
EvaluationOfElectromagneticDosimetry_2012.pdf
Size:
737.33 KB
Format:
Adobe Portable Document Format
Description: