Publication:
Assessment of regional pulmonary blood flow using Ga-68-DOTA PET

dc.contributor.authorVelasco, Carlos
dc.contributor.authorMateo, Jesus
dc.contributor.authorSantos, Arnoldo
dc.contributor.authorMota-Cobian, Adriana
dc.contributor.authorHerranz, Fernando
dc.contributor.authorPellico, Juan
dc.contributor.authorMota, Ruben A.
dc.contributor.authorEspana, Samuel
dc.contributor.authorRuiz-Cabello, Jesus
dc.contributor.funderMinisterio de Economía y Competitividad (España)
dc.contributor.funderInstituto de Salud Carlos III
dc.contributor.funderMinisterio de Educación, Cultura y Deporte (España)
dc.contributor.funderComunidad de Madrid (España)
dc.contributor.funderFundación ProCNIC
dc.date.accessioned2017-10-20T10:33:50Z
dc.date.available2017-10-20T10:33:50Z
dc.date.issued2017
dc.description.abstractBackground: In vivo determination of regional pulmonary blood flow (PBF) is a valuable tool for the evaluation of many lung diseases. In this study, the use of Ga-68-DOTA PET for the in vivo quantitative determination of regional PBF is proposed. This methodology was implemented and tested in healthy pigs and validated using fluorescent microspheres. The study was performed on young large white pigs (n = 4). To assess the reproducibility and consistency of the method, three PET scans were obtained for each animal. Each radiotracer injection was performed simultaneously to the injection of fluorescent microspheres. PBF images were generated applying a two-compartment exchange model over the dynamic PET images. PET and microspheres values were compared by regression analysis and Bland-Altman plot. Results: The capability of the proposed technique to produce 3D regional PBF images was demonstrated. The correlation evaluation between Ga-68-DOTA PET and microspheres showed a good and significant correlation (r = 0.74, P < 0.001). Conclusions: Assessment of PBF with the proposed technique allows combining the high quantitative accuracy of PET imaging with the use of Ga-68/Ge-68 generators. Thus, Ga-68-DOTA PET emerges as a potential inexpensive method for measuring PBF in clinical settings with an extended use.
dc.description.peerreviewed
dc.description.sponsorshipThis work was supported by a grant from the Spanish Ministry of Economy and Competitiveness (MINECO) (SAF2014-58920-R) and a grant from the Carlos III Institute of Health (FIS-FEDER PI14-01427). C. Velasco is a recipient of a fellowship from the Spanish Ministry of Education (FPU014/01794). S. Espana and A. Santos are recipients of M+Vision Advanced fellowships from the community of Madrid. The CNIC is supported by the MINECO and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (MINECO award SEV-2015-0505).
dc.format.volume7
dc.identifierISI:000392550700001
dc.identifier.citationEJNMMI Res. 2017; 7(1):7
dc.identifier.doi10.1186/s13550-017-0259-2
dc.identifier.issn2191-219X
dc.identifier.journalEJNMMI Research
dc.identifier.pubmedID28101850
dc.identifier.urihttp://hdl.handle.net/20.500.12105/5167
dc.language.isoeng
dc.publisherSpringer
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/SEV-2015-0505es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/SAF2014-58920-Res_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/PI14-01427es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/FPU014/01794es_ES
dc.relation.publisherversionhttps://doi.org/10.1186/s13550-017-0259-2
dc.repisalud.institucionCNIC
dc.repisalud.orgCNICCNIC::Unidades técnicas::Imagen Avanzada
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectPET
dc.subjectPulmonary blood flow
dc.subjectGallium-68
dc.subjectFluorescent microspheres
dc.subjectPOSITRON-EMISSION-TOMOGRAPHY
dc.subjectMYOCARDIAL-PERFUSION
dc.subjectLUNG PERFUSION
dc.subjectPIG MODEL
dc.subjectQUANTIFICATION
dc.subjectMICROSPHERES
dc.subjectVALIDATION
dc.subjectCT
dc.subjectDEPOSITION
dc.subjectVOLUME
dc.titleAssessment of regional pulmonary blood flow using Ga-68-DOTA PET
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication2354bf11-b233-4470-9d45-24b5f0d5f005
relation.isAuthorOfPublication87474fa8-0391-4061-976d-4576907ea30d
relation.isAuthorOfPublicationfe7e65af-23b4-41f1-a374-c7c969074a65
relation.isAuthorOfPublication9adc958d-9ef6-4528-b532-68f7f3ad937c
relation.isAuthorOfPublicationf0c202e0-8054-4f64-ba3c-a2c107d7cb48
relation.isAuthorOfPublication14fad52a-ce99-4d28-b74e-044dcfbe5b6a
relation.isAuthorOfPublicationbabdf5fd-574e-41f9-a91d-8648e6c9ed4b
relation.isAuthorOfPublicationaa5c6326-5e02-4c53-afad-fdf9c0115861
relation.isAuthorOfPublication845644de-01dd-4517-ab89-a07183d31248
relation.isAuthorOfPublication.latestForDiscovery2354bf11-b233-4470-9d45-24b5f0d5f005

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AssessmentOfRegionalPulmonaryBlood_2017
Size:
1.91 MB
Format:
Adobe Portable Document Format