Publication:
Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequences.

dc.contributor.authorGómez-Talavera, Sandra
dc.contributor.authorFernandez-Jimenez, Rodrigo
dc.contributor.authorFuster, Valentin
dc.contributor.authorNothnagel, Nils D
dc.contributor.authorKouwenhoven, Marc
dc.contributor.authorClemence, Matthew
dc.contributor.authorGarcía-Lunar, Inés
dc.contributor.authorGómez-Rubín, María C
dc.contributor.authorNavarro, Felipe
dc.contributor.authorPérez-Asenjo, Braulio
dc.contributor.authorFernández-Friera, Leticia
dc.contributor.authorCalero, María J
dc.contributor.authorOrejas, Miguel
dc.contributor.authorCabrera, José Ángel
dc.contributor.authorDesco, Manuel
dc.contributor.authorPizarro, Gonzalo
dc.contributor.authorIbáñez, Borja
dc.contributor.authorSánchez-González, Javier
dc.contributor.authorNothnagel, Nils D.
dc.contributor.authorGómez-Rubín, María C.
dc.contributor.authorCalero, María J.
dc.contributor.authorCabrera, José Ángel
dc.contributor.funderUnión Europea. Comisión Europea
dc.contributor.funderInstituto de Salud Carlos III
dc.contributor.funderUnión Europea. Comisión Europea. European Research Council (ERC)
dc.contributor.funderFundación ProCNIC
dc.contributor.funderComunidad de Madrid (España)
dc.date.accessioned2022-04-04T10:53:46Z
dc.date.available2022-04-04T10:53:46Z
dc.date.issued2021-09
dc.description.abstractThis study sought to clinically validate a novel 3-dimensional (3D) ultrafast cardiac magnetic resonance (CMR) protocol including cine (anatomy and function) and late gadolinium enhancement (LGE), each in a single breath-hold. CMR is the reference tool for cardiac imaging but is time-consuming. A protocol comprising isotropic 3D cine (Enhanced sensitivity encoding [SENSE] by Static Outer volume Subtraction [ESSOS]) and isotropic 3D LGE sequences was compared with a standard cine+LGE protocol in a prospective study of 107 patients (age 58 ± 11 years; 24% female). Left ventricular (LV) mass, volumes, and LV and right ventricular (RV) ejection fraction (LVEF, RVEF) were assessed by 3D ESSOS and 2D cine CMR. LGE (% LV) was assessed using 3D and 2D sequences. Three-dimensional and LGE acquisitions lasted 24 and 22 s, respectively. Three-dimensional and LGE images were of good quality and allowed quantification in all cases. Mean LVEF by 3D and 2D CMR were 51 ± 12% and 52 ± 12%, respectively, with excellent intermethod agreement (intraclass correlation coefficient [ICC]: 0.96; 95% confidence interval [CI]: 0.94 to 0.97) and insignificant bias. Mean RVEF 3D and 2D CMR were 60.4 ± 5.4% and 59.7 ± 5.2%, respectively, with acceptable intermethod agreement (ICC: 0.73; 95% CI: 0.63 to 0.81) and insignificant bias. Both 2D and 3D LGE showed excellent agreement, and intraobserver and interobserver agreement were excellent for 3D LGE. ESSOS single breath-hold 3D CMR allows accurate assessment of heart anatomy and function. Combining ESSOS with 3D LGE allows complete cardiac examination in <1 min of acquisition time. This protocol expands the indication for CMR, reduces costs, and increases patient comfort.es_ES
dc.description.peerreviewedes_ES
dc.description.sponsorshipFunding included Instituto de Salud Carlos III (ISCIII) and the European Regional Development Fund (ERDF) Grants DTS17/00136 to Dr. Ibáñez and PI19/01704 to Dr. Fernandez-Jimenez; Spanish Society of Cardiology Translational Research Grant 2016 to Dr. Ibáñez; European Research Council ERC-CoG 819775-MATRIX to Dr. Ibáñez; Comunidad de Madrid S2017/BMD-3867-RENIM-CM to Drs. Desco and Ibáñez; and Ministerio de Ciencia e Innovación (MICINN) RETOS2019-107332RB-I00 to Dr. Ibáñez. Dr. Fernandez-Jimenez received funding from the European Union Horizon 2020 research and innovation programme under Marie Skłodowska-Curie Hrant Agreement No. 707642. The CNIC is supported by the ISCIII, the MICINN, and the Pro CNIC Foundation. Drs. Fernandez-Jimenez, Nothnagel, Fuster, Ibáñez, and Javier Sánchez-González are inventors of a joint patent (Philips/CNIC) for the new cine imaging method here described and validated/protected under the IP #2014P00960EP. Drs. Nothnagel, Kouwenhoven, Clemence, and Javier Sánchez-González are Philips employees. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.es_ES
dc.format.number9es_ES
dc.format.page1742-1754es_ES
dc.format.volume14es_ES
dc.identifier.citationJACC Cardiovasc Imaging. 2021 Sep;14(9):1742-1754es_ES
dc.identifier.doi10.1016/j.jcmg.2021.02.031es_ES
dc.identifier.e-issn1876-7591es_ES
dc.identifier.issn1936-878Xes_ES
dc.identifier.journalJACC. Cardiovascular imaginges_ES
dc.identifier.pubmedID33865783es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/13916
dc.language.isoenges_ES
dc.publisherElsevier
dc.relation.projectFECYTinfo:eu-repo/grantAgreement/ES/S2017/BMD-3867-RENIM-CMes_ES
dc.relation.projectFECYTinfo:eu-repo/grantAgreement/ES/RETOS2019-107332RB-I00es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/DTS17/00136es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/PI19/0 1704es_ES
dc.repisalud.institucionCNICes_ES
dc.repisalud.orgCNICCNIC::Grupos de investigación::Laboratorio Traslacional para la Imagen y Terapia Cardiovasculares_ES
dc.repisalud.orgCNICCNIC::Grupos de investigación::Imagen Cardiovascular y Estudios Poblacionaleses_ES
dc.repisalud.orgCNICCNIC::Grupos de investigación: Imagen y Salud Cardiovasculares_ES
dc.repisalud.orgCNICpesaes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.licenseAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subject.meshContrast Mediaes_ES
dc.subject.meshMagnetic Resonance Imaging, Cinees_ES
dc.subject.meshAgedes_ES
dc.subject.meshFemalees_ES
dc.subject.meshGadoliniumes_ES
dc.subject.meshHumanses_ES
dc.subject.meshImaging, Three-Dimensionales_ES
dc.subject.meshMagnetic Resonance Spectroscopyes_ES
dc.subject.meshMalees_ES
dc.subject.meshMiddle Agedes_ES
dc.subject.meshPredictive Value of Testses_ES
dc.subject.meshProspective Studieses_ES
dc.subject.meshReproducibility of Resultses_ES
dc.titleClinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequences.es_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationa6bead57-638c-4bc1-96de-94d972aa3e2c
relation.isAuthorOfPublication558474d4-85be-4127-bda8-59128f707249
relation.isAuthorOfPublication3d8c68c5-1cf7-41e7-bc20-a44a703ae994
relation.isAuthorOfPublicationfd09339f-c3f0-46dd-8e0f-d2d60f267dfe
relation.isAuthorOfPublication2cac8bb6-2bff-4bf6-8209-bdbd21781786
relation.isAuthorOfPublication.latestForDiscoverya6bead57-638c-4bc1-96de-94d972aa3e2c
relation.isFunderOfPublication639cecfa-9455-4e7f-9f65-9ece17a878f0
relation.isFunderOfPublication7d739953-4b68-4675-b5bb-387a9ab74b66
relation.isFunderOfPublicationcb2ee04a-8d42-4a64-b3f6-3c156f222b35
relation.isFunderOfPublicationef935eeb-4c46-446a-868e-66e905683e75
relation.isFunderOfPublicationc87c70a3-e023-4b6b-ac25-1b2d1b483786
relation.isFunderOfPublication.latestForDiscovery639cecfa-9455-4e7f-9f65-9ece17a878f0
relation.isPublisherOfPublication7d471502-7bd5-4f7a-90a4-8274382509ef
relation.isPublisherOfPublication.latestForDiscovery7d471502-7bd5-4f7a-90a4-8274382509ef

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
1-s2.0-S1936878X21002849-main.pdf
Size:
2.43 MB
Format:
Adobe Portable Document Format
Description:
Main article
Loading...
Thumbnail Image
Name:
1-s2.0-S1936878X21002849-mmc8.pdf
Size:
1.2 MB
Format:
Adobe Portable Document Format
Description:
Supplemental material