Publication: Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object
| dc.contributor.author | García-Pérez, Pablo | |
| dc.contributor.author | Espana, Samuel | |
| dc.contributor.funder | Ministerio de Ciencia, Innovación y Universidades (España) | |
| dc.contributor.funder | Instituto de Salud Carlos III | |
| dc.contributor.funder | Fundación ProCNIC | |
| dc.contributor.funder | Comunidad de Madrid (España) | |
| dc.date.accessioned | 2020-03-30T14:28:12Z | |
| dc.date.available | 2020-03-30T14:28:12Z | |
| dc.date.issued | 2020-01-13 | |
| dc.description.abstract | BACKGROUND: Simultaneous reconstruction of emission and attenuation images in time-of-flight (TOF) positron emission tomography (PET) does not provide a unique solution. In this study, we propose to solve this limitation by including additional information given by a reference object with known attenuation placed outside the patient. Different configurations of the reference object were studied including geometry, material composition, and activity, and an optimal configuration was defined. In addition, this configuration was tested for different timing resolutions and noise levels. RESULTS: The proposed strategy was tested in 2D simulations obtained by forward projection of available PET/CT data and noise was included using Monte Carlo techniques. Obtained results suggest that the optimal configuration corresponds to a water cylinder inserted in the patient table and filled with activity. In that case, mean differences between reconstructed and true images were below 10%. However, better results can be obtained by increasing the activity of the reference object. CONCLUSION: This study shows promising results that might allow to obtain an accurate attenuation map from pure TOF-PET data without prior knowledge obtained from CT, MRI, or transmission scans. | es_ES |
| dc.description.peerreviewed | Sí | es_ES |
| dc.description.sponsorship | This work was supported by a grant from the Comunidad de Madrid (2016-T1/TIC-1099). The CNIC is supported by the Instituto de Salud Carlos III (ISCIII); the Ministerio de Ciencia, Innovación y Universidades (MCNU); and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505). | es_ES |
| dc.format.number | 1 | es_ES |
| dc.format.page | 3 | es_ES |
| dc.format.volume | 7 | es_ES |
| dc.identifier.citation | EJNMMI Phys. 2020; 7(1):3 | es_ES |
| dc.identifier.doi | 10.1186/s40658-020-0272-9 | es_ES |
| dc.identifier.issn | 2197-7364 | es_ES |
| dc.identifier.journal | EJNMMI physics | es_ES |
| dc.identifier.pubmedID | 31932984 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/20.500.12105/9371 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Springer | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/ES/SEV-2015-0505 | es_ES |
| dc.relation.publisherversion | https://doi.org/10.1186/s40658-020-0272-9 | es_ES |
| dc.repisalud.institucion | CNIC | es_ES |
| dc.repisalud.orgCNIC | CNIC::Grupos de investigación | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.license | Atribución 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
| dc.subject | Attenuation correction | es_ES |
| dc.subject | Joint reconstruction | es_ES |
| dc.subject | Positron emission tomography | es_ES |
| dc.subject | Time of flight | es_ES |
| dc.title | Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | VoR | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | aa5c6326-5e02-4c53-afad-fdf9c0115861 | |
| relation.isAuthorOfPublication.latestForDiscovery | aa5c6326-5e02-4c53-afad-fdf9c0115861 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- SimultaneousEmissionAttenuationReconstruction_2020.pdf
- Size:
- 2.98 MB
- Format:
- Adobe Portable Document Format
- Description:


