<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-21T23:03:15Z</responseDate><request verb="GetRecord" identifier="oai:repisalud.isciii.es:20.500.12105/12047" metadataPrefix="marc">https://repisalud.isciii.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:repisalud.isciii.es:20.500.12105/12047</identifier><datestamp>2025-06-25T10:41:22Z</datestamp><setSpec>com_20.500.12105_8142</setSpec><setSpec>com_20.500.12105_5570</setSpec><setSpec>com_20.500.12105_2404</setSpec><setSpec>com_20.500.12105_2403</setSpec><setSpec>col_20.500.12105_8172</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Armida Bretones, Rosa Mª</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Barbero del Palacio, P.</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Uribe LLopis, P.</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Valle Robles, María Luisa</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Mínguez Martínez, MªDolores</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Caso Pita, Covadonga</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2012-03</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">[ES] La preocupación creciente de los trabajadores hacia los posibles efectos nocivos de la exposición a campos electromagnéticos, está suponiendo una percepción desproporcionada de los riesgos derivados de la exposición. En la actualidad, no existe evidencia científica sobre dichos efectos nocivos, siendo aconsejable la vigilancia sobre las exposiciones que están fuera de los límites de seguridad. Desde este Servicio de Prevención y en colaboración con el Servicio de Física Médica, hemos elaborado un procedimiento que garantice, mediante criterios preventivos básicos, la seguridad y salud de los trabajadores que manejan equipos emisores de radiaciones no ionizantes, en nuestro hospital y centros de especialidades. Para la elaboración de este procedimiento hemos revisado la literatura científica relativa a los efectos de los campos electromagnéticos sobre la salud, reuniones periódicas de trabajo entre ambos servicios, identificación y ubicación de los equipos de radiaciones no ionizantes, y asesoramiento por expertos en la materia. El procedimiento establece medidas de control para los trabajadores, y medidas de control para los equipos. Con la finalidad de conseguir una buena difusión e implantación de dicho procedimiento, hemos elaborado dípticos y carteles, donde reflejamos las medidas de control para trabajadores y equipos: Onda Corta, Microondas, Magnetoterapia, Resonancia Magnética Nuclear, Láser y Ultravioleta El procedimiento con sus carteles explicativos ha sido distribuido específicamente por servicios, realizando formación e información de los trabajadores que maneja dichos equipos. [EN] Employee increasing concern about possible dangerous effects of the exposure to electromagnetic fields is meaning a distorted perception of the exposure related risks. Currently, there is no scientific evidence of the dangerous effects mentioned although surveillance over the exposures out of the safety limits is recommended. Within this Prevention Department in cooperation with The Medical Physics Department a procedure based on basic preventive criteria has been elaborated to guarantee health and safety of the employees who handle non-ionizing radiation emitting equipment in our hospital and specialized centers. To draw the procedure: scientific literature related to the electromagnetic fields effects over health has been checked, periodical working meetings have been held between both above mentioned departments; non-ionizing radiation equipment have been identified as well as the places they are based or used; and expert people advice has been used. The procedure sets control and follow-up measurements both for people and equipment such as follows: Shortwave, microwave and magnetic therapy, Nuclear magnetic resonance, Laser, Ultraviolet radiation. The procedure and illustrative posters have been deployed to the linked departments, the information and training having been given to the employees who work with kind of equipment.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">Med Segur Trab 2012; Vol.58 Nº 226;67-78</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">10.4321/S0465-546X2012000100008</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">1989-7790</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">0465-546X</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">Medicina y Seguridad del Trabajo</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">http://hdl.handle.net/20.500.12105/12047</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Radiaziones no ionizantes</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Riesgo</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Exposición laboral</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Normas de seguridad</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Non-ionizing radiation</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Risk</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Labor exposure</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Procedure</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Safety rules</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Normas básicas de seguridad durante el manejo de equipos de radiaciones no ionizantes</subfield>
   </datafield>
</record></metadata></record></GetRecord></OAI-PMH>