Publication:
Comparative Evaluation of Indirect Immunofluorescence and NS-1-Based ELISA to Determine Zika Virus-Specific IgM

Loading...
Thumbnail Image
Identifiers
Publication date
2018
Authors
Vazquez, Ana ISCIII ORCIDScopus Author IDWeb of Science ResearcherID
Montero, María Dolores
Sulleiro, Elena
Martínez, Miguel J
Matas, Lurdes
Merino, Francisco J
Advisors
Journal Title
Journal ISSN
Volume Title
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Metrics
Google Scholar
Export
Research Projects
Organizational Units
Journal Issue
Abstract
Differential diagnosis of the Zika virus (ZIKV) is hampered by cross-reactivity with other flaviviruses, mainly dengue viruses. The aim of this study was to compare two commercial methods for detecting ZIKV immunoglobulin M (IgM), an indirect immunofluorescence (IIF) and an enzyme immunoassay (ELISA), using the non-structural (NS) 1 protein as an antigen, both from EuroImmun, Germany. In total, 255 serum samples were analyzed, 203 of which showed laboratory markers of ZIKV infections (PCR-positive in serum and/or in urine and/or positive or indeterminate specific IgM). When tested with IIF, 163 samples were IgM-positive, while 13 samples were indeterminate and 78 were negative. When IIF-positive samples were tested using ELISA, we found 61 positive results, 14 indeterminate results, and 88 negative results. Among the indeterminate cases tested with IIF, ELISA analysis found two positive, two indeterminate, and nine negative results. Finally, 74 of the 78 IIF-negative samples proved also to be negative using ELISA. For the calculations, all indeterminate results were considered to be positive. The agreement, sensitivity, and specificity between ELISA and IIF were 60.2%, 44.9%, and 94.9%, respectively. Overall, 101 samples showed discrepant results; these samples were finally classified on the basis of other ZIKV diagnostic approaches (PCR-positive in serum and/or in urine, IgG determinations using IIF or ELISA, and ZIKV Plaque Reduction Neutralization test-positive), when available. A final classification of 228 samples was possible; 126 of them were positive and 102 were negative. The corresponding values of agreement, sensitivity, and specificity of IIF were 86.0%, 96.8%, and 72.5%, respectively. The corresponding figures for ELISA were 81.1%, 65.9%, and 100%, respectively. The ELISA and IIF methods are both adequate approaches for detecting ZIKV-specific IgM. However, considering their respective weaknesses (low sensitivity in ELISA and low specificity in IIF), serological results must be considered jointly with other laboratory results.
Description
DeCS Terms
Bibliographic citation
Viruses. 2018 Jul 19;10(7). pii: E379.
Document type