dc.contributor.author | Flores Muñoz, Concepción | |
dc.contributor.author | Manchado López, Francisco de Asís | |
dc.contributor.author | Ranchal Sánchez, Antonio | |
dc.date.accessioned | 2021-05-04T09:03:07Z | |
dc.date.available | 2021-05-04T09:03:07Z | |
dc.date.issued | 2019-03 | |
dc.identifier.citation | Med Segur Trab 2019 ; Vol.65 Nº 254; 37-48 | es_ES |
dc.identifier.issn | 0465-546x | es_ES |
dc.identifier.uri | http://hdl.handle.net/20.500.12105/12856 | |
dc.description | Originales | es_ES |
dc.description.abstract | [ES] Introducción: El personal teleoperador de las centrales de llamadas telefónicas, está sometido a ruido
ambiental y al nivel sonoro de los auriculares con el posible desarrollo de pérdida auditiva.
Objetivos: El objetivo principal del estudio fue evaluar si el tipo de sistema de auriculares empleado
por los teleoperadores de una central de llamadas influía sobre la aparición de pérdida auditiva asimétrica.
Material y métodos: Estudio observacional descriptivo realizado en teleoperadores de una central de
llamadas del sur de España. Muestreo oportunista a partir del examen de vigilancia de salud de 2018, con
audiometría y cuestionario auto-cumplimentado. La variable dependiente fue la presencia de pérdida auditiva
asimétrica (diferencia de umbral interaural de 15 dB o más en al menos una frecuencia). Se realizó análisis
bivariante, y se usaron los programas estadísticos SPSS versión 25 y EPIDAT versión 4.2.
Resultados: La pérdida auditiva asimétrica en la muestra estudiada se relacionaba significativamente
con la edad de los sujetos (Z =-3,606, p< 0,000), pero no con el tipo de sistema de auriculares utilizado ni
con otras variables sociodemográficas, laborales o clínicas analizadas.
Conclusiones: El uso de auriculares del sistema monoaural no parece influir sobre la pérdida auditiva
asimétrica en el personal teleoperador de la muestra estudiada. [EN] Introduction: The Call Center Phone Operator is subject to environmental noise and to the headphones volume sound with possible hearing loss effects.Objectives: The main objective of the study was to assess whether the type of headphone system used by call center operators incidenced the asymmetrical hearing loss.
Material and methods: Descriptive observational study carried out on teleoperators of a call centre in
the south of Spain. Opportunity sampling technique carried out from the health surveillance examination
from 2018, with audiometry and self-completed questionnaire. The dependent variable was the presence of
asymmetric hearing loss (interaural threshold value of 15 dB or more in at least one frequency). Bivariate
analysis was performed, and statistical programs SPSS version 25 and EPIDAT version 4.2 were used.
Results: Asymmetric hearing loss in the studied sample was significantly related to the age of the
subjects (Z =-3,606, p<0,000), but not to the type of headphone system used or to other socio-demographic,
occupational or clinical variables analysed.
Conclusions: The use of mono headphones does not seem to be related with an asymmetric hearing
loss in the telephone operators of the studied sample. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Instituto de Salud Carlos III | es_ES |
dc.publisher | Escuela Nacional de Medicina del Trabajo | es_ES |
dc.relation.isversionof | Publisher's version | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | central de llamadas | es_ES |
dc.subject | teleoperadores | es_ES |
dc.subject | pérdida auditiva unilateral | es_ES |
dc.subject | ambliaudia | es_ES |
dc.subject | vigilancia de la salud | es_ES |
dc.title | Sistema de auriculares en teleoperadores: estudio en una central de llamadas del sur de España | es_ES |
dc.title.alternative | Headset System in Teleoperators: Study in a Call Centre in Southern Spain | es_ES |
dc.type | Artículo | es_ES |
dc.rights.license | Atribución-NoComercial-CompartirIgual 4.0 Internacional | * |
dc.format.volume | 65 | es_ES |
dc.format.number | 254 | es_ES |
dc.format.page | 37-48 | es_ES |
dc.description.peerreviewed | No | es_ES |
dc.identifier.e-issn | 1989-7790 | es_ES |
dc.relation.publisherversion | http://gesdoc.isciii.es/gesdoccontroller?action=download&id=23/01/2020-1cf650ac14 | es_ES |
dc.identifier.journal | Medicina y Seguridad del trabajo | es_ES |
dc.repisalud.centro | ISCIII::Escuela Nacional de Medicina del Trabajo | es_ES |
dc.repisalud.institucion | ISCIII | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |