Show simple item record

dc.contributor.authorBarquero Sanz, Raquel
dc.contributor.authorRubio Sanz, Jesus
dc.contributor.authorRescalvo Santiago, Fernando
dc.date.accessioned2021-03-02T09:52:49Z
dc.date.available2021-03-02T09:52:49Z
dc.date.issued2012-03
dc.identifier.citationMed Segur Trab 2012; Vol.58 Nº 226;59-66es_ES
dc.identifier.issn0465-546Xes_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12105/12046
dc.descriptionCaso clínicoes_ES
dc.description.abstract[ES] En una sala de Electrofisiología del Servicio de Cardiología en donde se efectúan procedimientos guiados con rayos X de ablación con radiofrecuencia y de implantes de desfibrilador biventricular, se registraron dosis mensuales anormalmente elevadas en el dosímetro personal de solapa de una auxiliar de enfermería que trabaja en la misma, con valores de dosis equivalente personal, Hp(10), de 125 mSv y de dosis equivalente personal superficial, Hp(0.07) de 128.1 mSv. Ante la ansiedad producida en la trabajadora al conocer las lecturas de su dosímetro, y dado que no se dispone de precedentes investigados en la instalación, se ha realizado un estudio para dilucidar si la dosis registrada ha podido ser recibida por la trabajadora o si solo ha sido recibida por el dosímetro. Se hacen medidas con un monitor ambiental en condiciones simuladas de los procedimientos, para estimar las dosis reales que pueda recibir el personal de la sala. Se comparan estos valores con los del rendimiento del equipo de RX en haz directo medidos durante la revisión anual de control de calidad del mismo, concluyéndose que ha sido el dosímetro, y no la trabajadora, el que se ha expuesto a radiación directa, siendo la situación más probable la de que dicho dosímetro cayó sobre el tubo de RX, normalmente orientado hacia el techo, un tiempo del orden de 1 minuto. Paralelamente a estas estimaciones dosimétricas, el Servicio de Prevención de Riesgos Laborales realizó la vigilancia de la salud, concluyendo que la trabajadora no tenía ningún indicio de haber recibido dosis de la magnitud registrada por su dosímetro. [EN] In a room of electrophysiology from the cardiology service where procedures are made guided with X-Rays of ablation with radiofrequency and from implants ventricular defibrillation; there were registered monthly doses usually high in the same personal dosimeter flap of a nursing assistant who works there with values of equivalent personal doses, Hp (10), of superficial equivalent doses, Hp (0.07) of 128.1mSv. In view of the anxiety produced in the worker upon knowing the readings of its dosimeter, and since there is no disposition of precedents investigated in the facility, and it has been carried out a study for explaining if the doses registered could has been received by the worker if it is only received by the dosimeter.es_ES
dc.language.isospaes_ES
dc.publisherInstituto de Salud Carlos III (ISCIII). Escuela Nacional de Medicina del Trabajo (ENMT) es_ES
dc.type.hasVersionVoRes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectDosimetríaes_ES
dc.subjectRadiaciones ionizanteses_ES
dc.subjectExposición accidentales_ES
dc.subjectDosimetryes_ES
dc.subjectAccidental exposurees_ES
dc.subjectIonizing radiatones_ES
dc.titleDosis elevada en el dosímetro personal de una auxiliar de enfermería en Electrofisiologíaes_ES
dc.title.alternativeA high dose in the personal dosage meter of nursing assistant in Electrophysiology fielden
dc.title.alternativeA high dose in the personal dosage meter of nursing assistant in Electrophysiology fieldes_ES
dc.typeresearch articlees_ES
dc.rights.licenseAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.format.volume58es_ES
dc.format.number226es_ES
dc.format.page59-66es_ES
dc.identifier.doi10.4321/S0465-546X2012000100007es_ES
dc.description.peerreviewedNoes_ES
dc.identifier.e-issn1989-7790es_ES
dc.relation.publisherversionhttps://doi.org/10.4321/S0465-546X2012000100007es_ES
dc.identifier.journalMedicina y Seguridad del Trabajoes_ES
dc.repisalud.centroISCIIIes_ES
dc.repisalud.institucionISCIIIes_ES
dc.rights.accessRightsopen accesses_ES


Files in this item

Acceso Abierto
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial-CompartirIgual 4.0 Internacional